49
Update
Chapter 1
Understanding the Barcode Scanner
1.14 HARDWARE RESET
1.14.1 RESTORE SYSTEM DEFAULTS
Instead of having the scanner read “Restore System Defaults” barcode, you may use key
combination, as described below, to restore system defaults during operation.
1) Hold down the [Power/Delete] key.
2) When the scanner responds with two short beeps (high tone), press the [Trigger] key
for about 5 seconds. The scanner LED indicator becomes solid red for a while and
then goes off.
3) When the scanner responds with a long beep (high tone), release the keys. Its LED
indicator becomes solid red and goes off quickly.
Note: The scanner will restart itself automatically.
1.14.2 RESET CONNECTION
When the output interface is BT HID or BT SPP Master, the scanner will attempt to
maintain an established connection. To stop such re-connection, you may need to have
the scanner read “Reset Connection” or “Restore System Defaults” barcode to clear the
current connection record. Alternatively, you may use key combination, as described
below, to reset connection during operation.
1) Hold down the [Trigger] key, and then press the [Power/Delete] key for at least 5
seconds.
2) The scanner will respond with two short beeps (high tone). Wait for a while until the
scanner responds with a long beep (high tone), release the keys.
Note: (1) After reset connection by hardware, the scanner will not restart itself
automatically. It will resume to its previous operation except no connection.
(2) For 1660, firmware version 1.34 or later is required.