73
Chapter 3
Changing Symbology Settings
3.1 CODABAR
3.1.1 FOR 1D SCANNERS
By default, the scanner is set to read Codabar barcodes.
Advanced settings are provided as shown below.
Start/Stop Character
Select one of the four different start/stop character pairs.
Transmit Start/Stop Character
Decide whether to include the selected start/stop characters in the data being transmitted.
CLSI Conversion
Decide whether to strip the start/stop characters and insert a space after the first, fifth, and tenth
characters of a 14-character barcode.
This applies to 14-character barcodes only; barcode length does not include the start and stop
characters.